Reliable Agricultural Alarm Systems for Your Monitoring Needs
Alarm
In the agricultural sector, it is crucial to protect your livestock and maintain proper environmental conditions. Alarm systems specifically designed for agricultural barns offer a reliable solution to detect potential problems early and respond quickly to any irregularities.
By using alarm systems specifically developed for agricultural facilities, you can proactively respond to deviations and prevent potential issues. This leads to better animal health, higher productivity, and more efficient farm management.
Contact Kleventa, a specialized supplier of agricultural alarm systems, to discuss the possibilities and ensure optimal monitoring of your barn. Kleventa has the experience and expertise to deliver high-quality alarm systems specifically designed for agricultural applications. We understand the unique needs of the agricultural sector and can help you choose the right system to meet your specific requirements.
Alarm | our products
Alarm systems
With alarm systems for agricultural barns, you can proactively identify problems and respond quickly to ensure the health and safety of your livestock and/or crops. Monitoring environmental conditions and detecting faults at an early stage contribute to efficient farm management and help minimize losses.
Octalarm alarm dialer
A reliable alarm dialer is essential for a complete and effective alarm system. For this purpose, we offer the Octalarm series. The Octalarm-Touch is an alarm dialer designed for monitoring critical technical installations and processes. As soon as a malfunction occurs, the Octalarm-Touch initiates alarm calls, enabling timely action. Setup and daily use of the Octalarm-Touch are highly intuitive and user-friendly, thanks to the 7-inch touchscreen and the prominent LED status bar.
During initial setup, the configuration wizard assists in creating the necessary basic settings. A clear menu provides quick access to all important configurations, such as user details and alarm methods.
Octalarm Connect ensures immediate calling capabilities via GSM and VoIP/SIP. The Octalarm-IP is a versatile alarm dialer with a clear, user-friendly interface. It also offers the option of a second calling connection, for example via GSM, in case the primary connection fails. Please note! Due to the gradual phase-out of 2G and 3G networks by providers, the GSM functionality on this device will eventually be discontinued. We recommend considering the purchase of its successor, the Octalarm-Touch.
Alarm panel AS-AM-AL
These alarm panels are equipped with contact inputs to which fault contacts from control equipment, mains power monitors, or thermostats can be connected.
AS – Simple yet highly efficient. There are four different alarm panels available within this series. The front panel is clear and immediately shows where an alarm has occurred. Each input can be individually enabled or disabled. With the test button, you can test the connected siren, and if the mains power fails, the internal battery will activate the alarm.
AM – The AM-6 allows you to monitor six contacts independently. Each input can be individually enabled or disabled. The corresponding signal lights display the status. At a glance, it is clear whether a contact is at rest (LED off), in alarm (LED on), or has been disabled (LED blinking). The AM-6 is equipped with a memory function. If an alarm resets itself, you can still see which contact had the fault. This makes it easy to trace faults that occur repeatedly.
AL – This alarm controller features 10 independent alarm groups. Each alarm input is also linked to an alarm output, allowing you to set priorities in alarm handling. The buttons with corresponding signal lights clearly and easily inform you where a fault has been detected. The AL-10 communicates the alarm and its location to your desired output (siren and/or phone), enabling you to take action when necessary. Each alarm input can be individually enabled or disabled and has a default delay function of 30 minutes. This delay function can be activated during a notification via your phone. Additionally, a delay time can be set per input before it triggers the dialer. An optional key switch is available to prevent unauthorized deactivation of an alarm. It is also possible to connect the AL-10 to the FarmConnect system, allowing remote control of this alarm controller.
ASU alarm system
The alarm systems of the ASU series independently monitor barn temperatures. Separate temperature sensors provide continuous recording of the barn climate, and the system activates an alarm if the set thresholds are exceeded. The alarm system also features contact inputs for monitoring external functions and factors, such as climate control systems or door contacts. The clear panel layout of the ASU series immediately shows the alarm zone and whether it concerns a temperature alarm or an external alarm.
Thanks to the built-in temperature compensation, unnecessary alarms during high outdoor temperatures are avoided. The alarm systems in this series are powered by an internal battery equipped with an intelligent trickle charging system with temperature compensation, which is continuously monitored. This guarantees that the ASU series always provides maximum reliability for your business.
Emergency power supply ESE-24
Prevention is better than cure. In the event of a power outage, it is crucial that your animals immediately receive their primary necessity: fresh air. The ESE-24 is an emergency power supply for the EGM-100 winch motor. It ensures that the air inlets are opened when the external 24V power supply fails. For EGM-100a motors, you can predefine how far the inlet flaps should open in case of a power failure.
Fresh air guaranteed. The ESE-24 is installed between the climate controller and the EGM-100 winch motor. Besides responding to power outages, the ESE-24 can also react to other external threats. It features a control input that can be connected to an emergency thermostat or a voltage protection device.
FarmAfarlarm
FarmAlarm, the new alarm system from Stienen, complies with European laws and regulations. The system features at least two parallel connections to alert the livestock farmer directly. In addition, it uses a monitored connection, triggering an alarm if the connection is lost.
FarmAlarm operates independently of the mains power supply; in the event of a power failure, the system continues to function using a built-in emergency power supply. FarmAlarm is equipped with 10 monitored inputs, which are also suitable for connecting external equipment.